Middle Tennessee Office Products and Supplies - Middle Tennessee Office Products

Tripp Lite SU20KRT-1TF uninterruptible power supply (UPS) 20 kVA 18000 W 22 AC outlet(s)

Tripp Lite SU20KRT-1TF. Output power capacity: 20 kVA, Output power: 18000 W, Input operation voltage (min): 120 V. AC outlet types: C19 coupler, NEMA 5–15R, NEMA 5–20R, NEMA L6-30R, AC outlets quantity: 22 AC outlet(s). Typical backup time at full load: 4.3 min, Typical backup time at half load: 12.5 min, Battery recharge time: 8 h. Form factor: Rackmount/Tower, Product color: Black, Rack capacity: 14U. Width: 17.5" (445 mm), Depth: 25.8" (656 mm), Height: 5.16" (131 mm)
Manufacturer: Tripp Lite
SKU: 2783450
Manufacturer part number: SU20KRT-1TF
UPC: 0037332158260
MSRP: $21,312.72
$15,422.17
Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. - Tripp Lite SU20KRT-1TF 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 14U total rack/tower configuration - Offers enhanced fault-tolerance and reliability with N+1 configuration support and hot-swappable whole UPS replacement options - Unique configuration ties input, output and data connections of two standard 10kVA UPS systems via detachable parallel PDU to offer 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and lower - Included Parallel PDU with manual bypass switching enables hot-swappable replacement of either 10kVA power module at any supported load level, with no interruption to connected equipment - Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets - Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions - Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise - Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types - Maintains full-time sine wave output within 2% of selectable 208/240 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V - Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs - Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs - Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement - Rack / tower configuration installs in 14 total rack spaces (14U) with a maximum installed depth of only 32.5 in. / 82.6 cm - PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted - Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices - Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces - HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces - Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification - Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) - Supports Emergency Power Off (EPO) via built-in interface - Included rail kit supports 14U 19 inch rackmount installation in 4 post racks - Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (5 required for SU20KRT-1TF) - Optional 2-9USTAND supports upright tower placement (2 required for SU20KRT-1TF) - Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters - LED / LCD display panel rotates for viewing in rackmount or tower configurations - Network-grade AC surge and noise suppression - Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions - Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (output de-rates by 25%) - External battery packs are field replaceable and hot swappable
Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 14U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations. - Tripp Lite SU20KRT-1TF 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 14U total rack/tower configuration - Offers enhanced fault-tolerance and reliability with N+1 configuration support and hot-swappable whole UPS replacement options - Unique configuration ties input, output and data connections of two standard 10kVA UPS systems via detachable parallel PDU to offer 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and lower - Included Parallel PDU with manual bypass switching enables hot-swappable replacement of either 10kVA power module at any supported load level, with no interruption to connected equipment - Hardwire input; 2 L6-30R (208/240v), 8 C19 (208/240v), 8 5-15/20R (120v) and 4 5-15R (120v) outlets - Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions - Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise - Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types - Maintains full-time sine wave output within 2% of selectable 208/240 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V - Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs - Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs - Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement - Rack / tower configuration installs in 14 total rack spaces (14U) with a maximum installed depth of only 32.5 in. / 82.6 cm - PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted - Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices - Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces - HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces - Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification - Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) - Supports Emergency Power Off (EPO) via built-in interface - Included rail kit supports 14U 19 inch rackmount installation in 4 post racks - Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (5 required for SU20KRT-1TF) - Optional 2-9USTAND supports upright tower placement (2 required for SU20KRT-1TF) - Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters - LED / LCD display panel rotates for viewing in rackmount or tower configurations - Network-grade AC surge and noise suppression - Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions - Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (output de-rates by 25%) - External battery packs are field replaceable and hot swappable
Products specifications
Attribute nameAttribute value
Depth25.8"
Package weight630.1 lbs
Master (outer) case weight630.1 lbs
*
*
*
Products specifications
Attribute nameAttribute value
Depth25.8"
Package weight630.1 lbs
Master (outer) case weight630.1 lbs