Middle Tennessee Office Products and Supplies - Middle Tennessee Office Products

Tripp Lite S3MT-100K600V isolation transformer

Tripp Lite S3MT-100K600V. AC inlet type: Hardwire, AC outlet types: Hardwire, AC input voltage: 600 V. Width: 23.6" (599.4 mm), Depth: 33.5" (850.9 mm), Height: 47.2" (1198.9 mm). Quantity per master (outer) case: 1 pc(s), Master (outer) case width: 27.6" (701 mm), Master (outer) case length: 37.8" (960.1 mm)
Manufacturer: Tripp Lite
SKU: 6257933
Manufacturer part number: S3MT-100K600V
UPC: 0037332253170
MSRP: $15,912.00
$11,514.14
Get Complete Step-Down/Step-Up and Isolation Protection Tripp Lite’s S3MT-100K600V 100kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 600V electrical feed and 208/120V equipment.
Performs with High Efficiency up to 97.7% Not only is the S3MT-100K600V very efficient, with up to 97.7 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Three ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection.
Small Footprint for Quick Installation in a Compact Space The compact footprint enables installation of the S3MT-100K600V with minimal space. The rugged stainless steel housing ships ready for immediate tower installation with a compatible 80–100kVA/kW Tripp Lite S3M-Series 208V 3-phase UPS system.
Get Complete Step-Down/Step-Up and Isolation Protection Tripp Lite’s S3MT-100K600V 100kVA/kW transformer offers line isolation and protection to the connected 3-phase UPS system and its load. It isolates the UPS and connected components from line surges and spikes caused by utility power disruptions that can damage equipment or corrupt data. The step-down input isolation transformer is ideal for 4-wire (3Ph+N+PE) IT loads in government, manufacturing, healthcare and corporate settings with a 600V electrical feed and 208/120V equipment.
Performs with High Efficiency up to 97.7% Not only is the S3MT-100K600V very efficient, with up to 97.7 percent efficiency, but it is also very quiet with a noise profile less than 65 dBA. A built-in circuit breaker on the output side helps prevent dangerous power overloads. Three ball-bearing cooling fans help prevent overheating. An overheat-sensing relay and switch combine with a red LED indicator to provide over-temperature warning and overheating protection.
Small Footprint for Quick Installation in a Compact Space The compact footprint enables installation of the S3MT-100K600V with minimal space. The rugged stainless steel housing ships ready for immediate tower installation with a compatible 80–100kVA/kW Tripp Lite S3M-Series 208V 3-phase UPS system.
Products specifications
Attribute nameAttribute value
Weight1049 lbs
Load Capacity100000 VA
Package depth37.8"
Package height55.1"
Package weight1102.1 lbs
Cooling typeFan
AC input voltage600 V
Efficiency96.7 %
Heat dissipation11263 BTU/h
Master (outer) case weight1102.1 lbs
Master (outer) case length37.8"
Master (outer) case width27.6"
Master (outer) case height55.1"
AC inlet typeHardwire
AC output voltage120 - 208 V
Input current (input transformer)134 A
Inrush current (input transformer)1160 A
Efficiency (@half load)97.7 %
Bottom panel(s) includedY
Number of bottom panels4
Output current (output transformer)374 A
*
*
*
Products specifications
Attribute nameAttribute value
Weight1049 lbs
Load Capacity100000 VA
Package depth37.8"
Package height55.1"
Package weight1102.1 lbs
Cooling typeFan
AC input voltage600 V
Efficiency96.7 %
Heat dissipation11263 BTU/h
Master (outer) case weight1102.1 lbs
Master (outer) case length37.8"
Master (outer) case width27.6"
Master (outer) case height55.1"
AC inlet typeHardwire
AC output voltage120 - 208 V
Input current (input transformer)134 A
Inrush current (input transformer)1160 A
Efficiency (@half load)97.7 %
Bottom panel(s) includedY
Number of bottom panels4
Output current (output transformer)374 A